Applied Energistics 2

Applied Energistics 2

137M Downloads

ME-system stopping

geozukunft opened this issue · 6 comments

commented

Hello I have a problem I have a ME-system with about 90 channels used and a few days ago the system suddenly disconnected every device. Each device was writing no channel used. Then I disconneted the fluix cable that was beetween the energy acceptor and the energycell after a few seconds the system did something like a reboot and everything worked fine again and I placed the fluix cable again. But a few minutes later there was again the same issue.

Is this a problem of my client or of the software or a bug of the modß

Hope somebody can help me.

geozukunft

commented

Screenshots, or a video, would help.

commented

Sounds like insufficient power. Make sure you are producing enough.

I'll assume you already checked that; so when that is a dead end, try adding a few AE2 Energy Cells around the system. I've heard that large systems can develop power problems due to not having a large enough AE2 power capacity on hand to deal with any server lag.

commented

Possibly, but I don't think so. Is your system SO big that parts of it could be in unloaded chunks?

commented

Yes there are a few ME-consoles and import buses that are nearly everytime unloaded and I have a Quantum Link where the other end is about 1500 blocks away. so there are things that are unloaded yes.

commented

network1
network2

commented

2016-07-06_20 10 37
2016-07-06_20 10 41
2016-07-06_20 10 49
2016-07-06_20 11 02
2016-07-08_21 29 34
2016-07-08_21 29 40
2016-07-08_21 29 51
I also thought it could be a power problem as you can see in the screenshots the tooltip writes 0 EU out of 4K EU. I placed nearly 20 Energy Cells but it was still crashing so I put a creativ Energy Cell but that does not help in any way. Could it be that the things that are far away consume more energy so the cable looses so much energy that it consumes so much energy from the Cell that the fluix cable can't transport so much energy?