Make control/informational machines not require channels
shartte opened this issue ยท 5 comments
This might already be the case but should be formalized:
The only machines that should require channels should be ones that convert energy to/from items, or that conduct it (P2P, Spatial, etc.)
This would mean the following parts should not require channels:
- All Level Emitters
- Storage Monitor (Conversion Monitor should, since it can output items)
@Technici4n What do you think about this?
No, i am terribly sorry, i must have accidentially reopened it while reading on my phone
@mindforger I closed it because I merged PR #5616. Is there something you would like to add?