Big Reactors

Big Reactors

11M Downloads

ender io conduits

krismoellegaard opened this issue · 4 comments

commented

i notis tha ender io conduits stop conecting to the reactor after som time energy coundue still transfer power but the redstone one dos not ill post a screen shot too (wen i get the time)

commented

Please include a BR version, EnderIO version and Forge version, along with
the screenshots please.

On Fri, May 30, 2014 at 3:47 PM, krismoellegaard [email protected]
wrote:

i notis tha ender io conduits stop conecting to the reactor after som time
energy coundue still transfer power but the redstone one dos not ill post a
screen shot too (wen i get the time)


Reply to this email directly or view it on GitHub
#201.

commented

2014-05-30_18 01 49
big reactor vertion 0,3,3A ender io vertion 1,6,4-1,05,0 forge i think is 9.11.1.965 screen shot com wen it happen agen

commented

This appears to be a graphical bug in EnderIO. See how the BR power tap lights up? That means it's detected a connection to an RF network.

commented

the problem is not with the energy the problem is with the redstone one it dosen sent a signal to the reactor witch mean it weill not start screen shot foloes

2014-06-01_23 16 43
as you can see it not conected

2014-06-01_23 16 47
and it not online

2014-06-01_23 29 20
reactor is conected

2014-06-01_23 17 09
and online

the problem is with the redstone port not receving the signal even tho the counduet is sendig it out