Can't switch fluid port modes.
windvlaag opened this issue ยท 5 comments
Both the turbine and reactor fluid port modes are unable to be switched. and are both on inlet mode.
Same problem:
CoFHCore 3.0.0B7-35
Big Reactors 0.4.0rc10
forge version 10.13.2.1230
Persists with a restart on both client and server.
Trying to switch with bare hand.
I'm going to need more information here. At a minimum, I need to know:
- Which Forge and Big Reactors versions you're using
- Whether this reproduces in SMP, SSP or both
- If you're using BR in a modpack, a link or modlist would be handy
- Did this happen once, or is it an ongoing problem? Does it persist through restarting your client/server?
- How are you trying to switch them? Via wrench? If so, which mod's wrench item are you using?
Found that a cresent hammer is the only working item, bare handed does not work.
This is on a multiplayer server was trying to switch barehand and with yeta wrench, and AE2 wrenches.
Big reactors 0.4.0.rc8.
CoFHCore 3.0.0B6-32.
Forge 10.13.0.1206
As of 0.4.0rc5, fluid ports can only be toggled with wrenches. See the patch notes:
https://github.com/erogenousbeef/BigReactors/blob/master/Changelog.md#040rc5