GregTechCEu Modern

GregTechCEu Modern

6M Downloads

Replacing a drum causes electric pumps to stop working

G1R-Productions opened this issue ยท 3 comments

commented

Checked for existing issues

  • I have checked for existing issues, and have found none.

Tested latest version

  • I have checked that this occurs on the latest version.

GregTech CEu Version

1.1.3.b

Recipe Viewer Installed

None

Environment

Dedicated server

Cross-Mod Interaction

Yes

Other Installed Mods

Gravitas2

Expected Behavior

Replacing an empty drum with a full drum while connected to an electric pump and fluid storage should empty the full drum

Actual Behavior

Replacing an empty drum with a full drum results in the new full drum not being emptied until the pipe with the pump is broken and replaced with the pump.

Steps to Reproduce

Empty a drum from the side with an electric pump then break the empty drum and place down a new full drum.

Additional Information

No response

commented

My current work around is to place a drum down and put a pump on that drum set to input. On one side I have a pipe with a pump to a tank and on the side with the pump I can put down a full drum and it will drain. When that drum is empty I can place a new drum. This is super janky but it works until the pump on a pipe is fixed.

commented

Item pipes with Conveyor Modules behave exactly like this! If I break a barrel with a pipe connected with it via conveyor module, then the whole pipe network doesn't behave like it must to. Building something automated with GT pipes causes a lot of issues and struggling :(

commented

fixed as of 1.5.0