Hbm's Nuclear Tech Mod

Hbm's Nuclear Tech Mod

1M Downloads

Heatsinks caused PWR meltdown

R-Kaenbyou opened this issue ยท 8 comments

commented

For a PWR which includes 215 or more heatsinks, it would explode immediately after the construction finished.

commented

I would love to a see a video of this

commented

how did bro find out that it is EXACTLY 215 or more heatsinks

commented

how did bro find out that it is EXACTLY 215 or more heatsinks

I've done many experiments; you can try it by yourself.

commented

how did bro find out that it is EXACTLY 215 or more heatsinks

Because bob got something wrong in the code. 215 heatsinks will lead to overflow, and the PWR heat capacity will become a negative number, so the reactor will meltdown immediately as it finished

commented

why are you using 215 heatsinks

commented

why are you using 215 heatsinks

I was trying to find out that how powerful can PWR be.

commented

I remember when i was doing that too, perhaps we should join our research

commented

I remember when i was doing that too, perhaps we should join our research

Someone else already found the result, 214 heatsinks can lead to the maximum output of 544.36MHE/s