Immersive Engineering

Immersive Engineering

134M Downloads

[1.18.2] Diesel Generator runs infinite power supply with just initial fuel bucket

IcedForge opened this issue ยท 0 comments

commented

Minecraft Version

1.18

Immersive Engineering Version

8.2.2-154

Expected Behavior

Diesel Generator stop working once it completely runs out of fuel.

Actual Behavior

Diesel generator runs infinitely without fuel supply once initiated and enabled.
https://i.gyazo.com/67bf5d77b77bf60a54eaead4e1e31a95.mp4

(Power gauge with measuring tool has it run down to 4kFE then "reset" back to 8kFE looped)

Steps to reproduce

  1. Create diesel generator multiblock, add a pipe and add a barrel
  2. Connect generator to powergrid with constant pull (excavator in this case)
  3. Fill barrel with a bucket of fuel
  4. Break the pipe connecting the barrel of fuel and the generator and watch it keep supplying power indefinitely.

Screenshot_44
Screenshot_45

Reproduced with a clean install of IE in creative
Screenshot_46

Debug Crash Log

https://pastebin.com/F2gDGZ8Z