Chemical Crystalizer is ignoring side config
utoc opened this issue ยท 2 comments
Good morning,
I am running Mekanism .232 at this time with FML 1448. I have found a bug with the chemical crystalizer ignoring the side config and only pulling gas from the left. All side config options are ignored for gas. See the screenshots below. Full mod list here: https://www.reddit.com/r/BBQSauce/wiki/modlist
Side config: http://i.imgur.com/wWsZOj2.png
It doesn't accept the gas from that side:
http://i.imgur.com/QPTIqZ0.png
The only workable solution:
http://i.imgur.com/uN9La3C.png
Let me know if there is any way I can assist
That's because you're configuring the item panel of the side config. On the config interface, hit the "warning" label symbolizing gas, and then configure that. You'll be all set :)