Thermal evaporation won't output brine into mechanical pipe.
Coolfeather2 opened this issue ยท 6 comments
Please use the search functionality before reporting an issue. Also take a look at the closed issues!
Issue description:
The Thermal Evaporation plant does not extract brine to the mechanical plant
Steps to reproduce:
- Construct Thermal Evaporation plant
- Put two thermal evaporation valves o, one for water, one for brine
- Water is drawn into the Thermal Evaporation plant
- No brine comes out
- Tried every configuration mode on the pipe on block, all it does is change the redstone signal mode
Version (make sure you are on the latest version before reporting):
Forge: 12.18.3.2281
Mekanism: 9.2.3
Other relevant version:
If a (crash)log is relevant for this issue, link it here: (It's almost always relevant)
[gist/pastebin/etc link here]
For anyone else with my same issue: if the Configurator isn't letting you configure pipes, you might have accidentally changed its mode. I had changed it to Wrench mode without realizing, so using it would just break pipes. I used the "Item mode key" from Controls, which brought up a radial menu which I could set to fluid mde, which allowed me configure pipes with push / pull again.
@farrspace @freerk92 @thiakil I needed these 3 answers combined to figure this out. Thank you!
You need to set the Mechanical Pipe to Pull mode. With the Configurator in Configure mode you need to sneak right click of the end of the pipe that touches the TEP