Modular Force Field Systems (MFFS)

Modular Force Field Systems (MFFS)

5M Downloads

Fortron capacitor has ghost device

Arano-kai opened this issue ยท 3 comments

commented

Ver: Mffs-1.7.10-0.0.41b1-universal
Mods: [email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected],[email protected]

Lonely capacitor has a ghost device (linked devices 1) at every freq, that eats energy. It even eat energy if mod set to fill. Also, capacity upgrade not working...
Tested on local server and Termos-58 (F1614)

commented

Capacitor upgrade should be fixed now.

As for the device eating energy & showing ghost devies -> This is not a bug, just like the original MFFS, the capacitor counts itself as a connected devices, and actually drains energy regardless if its working.

Although the original had this issue/design I have been looking at ways to adjust it.

commented

This is very similar to my issue - the capacitor will not store energy by any means.

commented

the capacitor counts itself as a connected devices

Then maybe make that more obvious: change Linked device to something like Devices on frequency or so...

and actually drains energy regardless if its working

Hmmm, drain/s meter in gui? I noticed, that drain depends from installed speed upgrades.