NuclearCraft

NuclearCraft

31M Downloads

Nuclearcraft Cooling Overflow

NielsPilgaard opened this issue ยท 4 comments

commented

Hey! This issue was reported on my tracker: EnigmaticaModpacks/Enigmatica2ExpertSkyblock#221
I'll copy paste it here, I hope you don't mind.

Issue Description
Large Nuclearcraft fission reactors, with active cooling, can overflow the cooling rate value, as it can go over 65535, and NC doesn't handle that. Apparently default NC config cooling values were "recently" updated, but not sure when, so the config may need a regen. Or if the heat values were intentionally boosted, they may need to just be set to normal. If the coolers are set to half efficiency that could maintain the 'difficulty' if that was the case

Just an example:
Nearly overflowing:
2018-11-10_18 29 13
Then with one more cooler:
2018-11-10_18 28 55

Version

1.12.2-2.12f

commented

\o/ thanks!

commented

Finally fixed for the next version :)

commented

Cheers Niller - yep, this is a known problem. Will get it sorted! The reactor should still run fine, it's just the GUI numbers that mess up :)

commented

Ah alright, thanks!