PneumaticCraft: Repressurized

PneumaticCraft: Repressurized

43M Downloads

Fluid Dupe Bug

MuteTiefling opened this issue ยท 4 comments

commented

Minecraft Version

1.15.2

Forge Version

forge-31.1.74

Mod Version

pneumaticcraft-repressurized-1.15.2-1.1.1-14

Describe your problem, including steps to reproduce it

Cross mod interaction. I've placed a Liquid Hopper on a Mekanism Dynamic Tank (directly on the valve). It appears to be endlessly extracting from the Dynamic Tank.

Any other comments?

https://streamable.com/tl4uvx

Log: https://gist.github.com/MuteTiefling/35035792f5d37b3dc23c97a931ba7190

commented

Not seeing that behaviour in my test world (dedicated server, Mekanism 9.10.2.415). I can see the liquid level in the Dynamic Tank steadily dropping as the liquid hopper extracts, just as expected.

commented

I'd recommend re-testing with the latest Mek (https://www.curseforge.com/minecraft/mc-mods/mekanism/files/2952808) - I know they're updating pretty fast over there.

commented

Ah, hadn't realized I was on an old version with that. Fair enough. Probably been fixed already

commented

Think this can be closed. Seems to be fine with up-to-date Mek releases.