PneumaticCraft: Repressurized

PneumaticCraft: Repressurized

50M Downloads

Can't discharge items in Charging Station

aaronhowser1 opened this issue ยท 4 comments

commented

For feature requests, just erase this template and clearly describe the feature you'd like to see

Minecraft Version

1.12

Forge Version

14.23.5.2847

Mod Version

1.12.2-0.11.14-395

Describe your problem, including steps to reproduce it

image
image
The pressure in the Charging Station is 0 bar and the pressure in the Canister is 20 bar, but the Charging Station says that they're equalized and won't discharge. Am I doing it wrong?

commented

No that should work. I tested and I can see the problem too, although it doesn't always fail...

commented

Build 396 from https://jenkins.k-4u.nl/job/PneumaticCraft-Repressurized/ should fix this. Was a bug that caused the charging station not to allow any air transfer if its pressure was at 0.

You can use the dev build until the 0.11.5 release, or work around the issue by putting a tiny bit of air into the charging station.

commented

Thank you very much ๐Ÿ‘

commented

Fixed in 0.11.15 release