Project Red - Fabrication

Project Red - Fabrication

19M Downloads

Wire not turning off.

NightOps007 opened this issue ยท 3 comments

commented

I was doing some playing around with your mods and quickly discovered that the wires are bugged.
Mods installed are as follows:
Forge(7.99.36.1558)
ForgeRelocation-0.0.1.4-universal
ProjectRed-1.7.10-4.7.0pre11.94-Compat
ProjectRed-1.7.10-4.7.0pre11.94-Base
ProjectRed-1.7.10-4.7.0pre11.94-Mechanical
ProjectRed-1.7.10-4.7.0pre11.94-World
ProjectRed-1.7.10-4.7.0pre11.94-Fabrication
ProjectRed-1.7.10-4.7.0pre11.94-Lighting
ProjectRed-1.7.10-4.7.0pre11.94-Integration
multipart(1.7.10-1.2.0.345)
MrTJPCore(1.1.0.33)
After red alloy wire or insulated wire were turned on, if they had more than 1 wire, they would not turn off again without updating the wire as shown in vid: https://youtu.be/mh4jUPtRGxE

commented

Did some further testing and discovered that this problem is new to the latest version; did not exist in pre11.93 version.

commented

Lol, major derp on my part. Fixed with c9e29a7.

commented

Yeah, same. Thanks for the fix!