Controller taking as much EU as possible
tenjaa opened this issue ยท 2 comments
Issue description:
We are playing with Industrial Craft and the Controller takes as much EU as possible.
What happens:
The controller says it needs 74 RS/t. That should be ~19 EU/t.
When connected to a CESU (max output: 128 EU/t) the controller takes 128EU/t. With a LV-Transformator (max output: 32EU/t) the controller just takes 32 EU/t.
What you expected to happen:
The controller should take 19 EU/t.
Steps to reproduce:
- Plant a controller and some things that consume RS.
- Build a CESU and put an advanced Battery in it to charge it.
- Connect the Controller with the CESU by Copper Cables.
- Measure the EU Out/Input with an EU-Reader. It says 128 EU/t.
- Put an LV-Transformater between Controller and CESU.
- Repeat step 4 and you see 32 EU/t.
Version (Make sure you are on the latest version before reporting):
- Minecraft: 1.10.2
- Forge: 12.18.3.2185
- Refined Storage: 1.2.14
- Industrial Craft 2: 2.6.140-ex110
Does this issue occur on a server? yes
I can provide screenshots, if required.
I addition to this we noticed that the output of an LV-Transformer is (always enough).
The controller says it needs 226 RS/t (56.5EU/t). The LV-Transformer has a max output of 32EU/t.
But the controller wont go empty.
The in- and output was again verified by the EU-Reader.