RFTools

RFTools

74M Downloads

Possible Powercell channel bug?

Selway00 opened this issue ยท 8 comments

commented

One of the channels in my Powercell network appears to be bugged. It is not drawing or sending power. When I insert the troubled channel card into any powercell, the power indicator disappears and shows a fantastically negative number. When I remove the card, the power bar returns to normal.

Other things I have tried:
My powercells and other channels appear to be operating normally.
I have also borken and replaced them multiple times.
I have tried relogging completely.
I have plenty of power available.
I have tested it on another isolated system and the channel is still bugged.

I am running the latest version of Age of Engineering.
RFtools 1.1x-1.6.8
Rftools dimensions 1.1x-5.05

Here are some pictures if it helps.

https://imgur.com/gallery/6Zyaa

Incredible mods! Thanks for them!

commented

That's an old version of rftools. This overflow bug has been fixed since. You exceeded 2 billion RF

commented

Ahhh. OK. Hey thanks for the quick reply. Cheers

commented

Are you saying that if I exceed 2 billion accumulated RF transmitted it will bug out? Or if it tries to remove or add power from a storage source greater than 2billion?

commented

sounds like there was a bug when you exceeded 2billion rf using that old version.

commented

yes and even in the latest version you cannot put more then 2 billion rf in

commented

So the work around is not to have any power STORAGE greater than 2Billion RF?

commented

Yes

commented

Gotcha. Thank you!