Import and export cause bug
landerf opened this issue ยท 11 comments
The export bus don't go on my AE cable, they channel go on and they skip on my cable. (4 Export on blank AE cable with 0 channel used and thez skip on :/ )
I'm french not english sorry.
What kind of cable are you using? They will not attach to a Dense cable.
What version of AE2 are you using? AE2 RV3 is not currently supported.
I'm not sure I understand the issue. It looks like the export buses are properly attached to the cable. The cable texture leads me to assume that there is not an ME controller on the network, are there more than 8 devices on the network? Also, does the network have power?
If you can, make the network tool(http://ae-mod.info/Network-Tool/), and right-click on the cable. It will list all attached devices and the current power state.
Okay, whenever you are able too, try testing out a single export bus to see if it works.
Make sure there is essentia stored in the network, then set the export filter. It should begin filling up the adjacent warded jar. If it works as expected, then we can assume it is just a visual glitch.
Yes , the jar go fill, it's just a visual glitch but i fear don't works :/ thanks :)