filled pressure pipe not connecting

Zoratan opened this issue ยท 1 comments

commented

Issue description:

pressure pipes dont connect to new ones when they are already filled.
i can connect and disconnect empty pipes with the configurator.
two pipes filled with the same gas are also (re)connectable.
but new pipes refuse to join

Steps to reproduce:

  1. place a creative filled gas tank (or a factory that produces a gas) and connect a pressure pipe with it
    2.once it is filled no additional pipe can be connected to the first one

Version (make sure you are on the latest version before reporting):

**Forge 1.15.2-31.0.14
**Mekanism: 1.15.2-9.9.8.400

commented

Closing this as it is fixed in 9.9.9, which is now released and on curseforge.