Mekanism Additions

Mekanism Additions

21M Downloads

Can't get Steam Gas from Boiler Multistructure

Karunkh opened this issue ยท 4 comments

commented

i got the newest Version of Mekanism for MC 1.16.1 and the Boiler works just fine except you can't extract the produced Steam.

commented

Hey,
I'm playing with Karunkh on the same Server and could send some Screenshots later.
But we can tell you, that there is nothing wrong with the boiler itself. It produces a lot of steam, but we can't get it out of there.
we have a boiler valve on steam catch layer and tried to use it as output to drive our turbine.
We tried both pipes and tubes to move the steam out, but it won't work :/

commented

I think the confusion may be that the boiler valve in V10 now has multiple modes so you need to set it to the proper output mode with a configurator.

commented

can you send a screenshot of the structure?

commented

Thank You very much!
We were confused^^
Now everything is fine ;)

Honor Brother!